WEKO3
アイテム
{"_buckets": {"deposit": "4c6c042d-c915-4022-8172-7ba19c51f60e"}, "_deposit": {"created_by": 30, "id": "1493", "owners": [30], "pid": {"revision_id": 0, "type": "depid", "value": "1493"}, "status": "published"}, "_oai": {"id": "oai:oist.repo.nii.ac.jp:00001493", "sets": ["54"]}, "author_link": ["9032", "9031", "9033"], "item_10001_biblio_info_7": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-03-23", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicVolumeNumber": "1", "bibliographic_titles": [{}, {"bibliographic_title": "View", "bibliographic_titleLang": "en"}]}]}, "item_10001_creator_3": {"attribute_name": "Author", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sathish, Shivani"}], "nameIdentifiers": [{"nameIdentifier": "9031", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Toda‐Peters, Kazumi"}], "nameIdentifiers": [{"nameIdentifier": "9032", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shen, Amy Q."}], "nameIdentifiers": [{"nameIdentifier": "9033", "nameIdentifierScheme": "WEKO"}]}]}, "item_10001_description_5": {"attribute_name": "Abstract", "attribute_value_mlt": [{"subitem_description": "Large populations around the world suffer from numerous but treatable health issues, caused by either lifestyle choices or environmental factors. Over the past decades, point-of-care testing kits have been developed to circumvent the reliance on laboratories, by allowing users to perform preliminary health or environmental testing from the privacy of their homes. However, these kits heavily rely on the precision of the user to perform the procedures, leading to increased variability in final assessments. To eliminate user-induced errors, we present an integrated, completely sealed, and disposable point-of-care testing prototype that exploits the benefits of microfluidics and 3D-printing fabrication techniques. The palm-sized modular prototype consists of a manually operated fluid handling device that allows precise mixing, filtration, and delivery of fluids to an on-board microfluidic assay unit for subsequent detection of specific biochemical analytes, with a minimized risk of contamination.", "subitem_description_type": "Other"}]}, "item_10001_publisher_8": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_publisher": "John Wiley \u0026 Sons Australia,Ltd"}, {"subitem_publisher": "Shanghai Fuji Technology Consulting Co., Ltd, authorized by Professional Community of Experimental Medicine, National Association of Health Industry and Enterprise Management (PCEM)"}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "info:doi/10.1002/viw2.1", "subitem_relation_type_select": "DOI"}}]}, "item_10001_relation_16": {"attribute_name": "情報源", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "https://creativecommons.org/licenses/by/4.0/"}]}]}, "item_10001_relation_17": {"attribute_name": "Related site", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://onlinelibrary.wiley.com/doi/10.1002/viw2.1", "subitem_relation_type_select": "URI"}}]}, "item_10001_rights_15": {"attribute_name": "Rights", "attribute_value_mlt": [{"subitem_rights": "© 2020 The Author(s)"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2688-268X", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_version_type_20": {"attribute_name": "Author\u0027s flag", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-05-13"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "viw2.1.pdf", "filesize": [{"value": "538.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "Creative Commons Attribution 4.0 International(https://creativecommons.org/licenses/by/4.0/)", "licensetype": "license_free", "mimetype": "application/pdf", "size": 538200.0, "url": {"label": "viw2.1", "url": "https://oist.repo.nii.ac.jp/record/1493/files/viw2.1.pdf"}, "version_id": "cc9e4710-d90b-4131-8329-92c187c3eda4"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Proof‐of‐concept modular fluid handling prototype integrated with microfluidic biochemical assay modules for point‐of‐care testing", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Proof‐of‐concept modular fluid handling prototype integrated with microfluidic biochemical assay modules for point‐of‐care testing", "subitem_title_language": "en"}]}, "item_type_id": "10001", "owner": "30", "path": ["54"], "permalink_uri": "https://oist.repo.nii.ac.jp/records/1493", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-05-13"}, "publish_date": "2020-05-13", "publish_status": "0", "recid": "1493", "relation": {}, "relation_version_is_last": true, "title": ["Proof‐of‐concept modular fluid handling prototype integrated with microfluidic biochemical assay modules for point‐of‐care testing"], "weko_shared_id": 30}
Proof‐of‐concept modular fluid handling prototype integrated with microfluidic biochemical assay modules for point‐of‐care testing
https://oist.repo.nii.ac.jp/records/1493
https://oist.repo.nii.ac.jp/records/149311ab1f28-c6c9-490e-82fc-b153409e6d49
名前 / ファイル | ライセンス | アクション |
---|---|---|
viw2.1 (538.2 kB)
|
Creative Commons Attribution 4.0 International(https://creativecommons.org/licenses/by/4.0/)
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-05-13 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Proof‐of‐concept modular fluid handling prototype integrated with microfluidic biochemical assay modules for point‐of‐care testing | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者(英) |
Sathish, Shivani
× Sathish, Shivani× Toda‐Peters, Kazumi× Shen, Amy Q. |
|||||
書誌情報 |
en : View 巻 1, 号 1, 発行日 2020-03-23 |
|||||
抄録 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Large populations around the world suffer from numerous but treatable health issues, caused by either lifestyle choices or environmental factors. Over the past decades, point-of-care testing kits have been developed to circumvent the reliance on laboratories, by allowing users to perform preliminary health or environmental testing from the privacy of their homes. However, these kits heavily rely on the precision of the user to perform the procedures, leading to increased variability in final assessments. To eliminate user-induced errors, we present an integrated, completely sealed, and disposable point-of-care testing prototype that exploits the benefits of microfluidics and 3D-printing fabrication techniques. The palm-sized modular prototype consists of a manually operated fluid handling device that allows precise mixing, filtration, and delivery of fluids to an on-board microfluidic assay unit for subsequent detection of specific biochemical analytes, with a minimized risk of contamination. | |||||
出版者 | ||||||
出版者 | John Wiley & Sons Australia,Ltd | |||||
出版者 | ||||||
出版者 | Shanghai Fuji Technology Consulting Co., Ltd, authorized by Professional Community of Experimental Medicine, National Association of Health Industry and Enterprise Management (PCEM) | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2688-268X | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | info:doi/10.1002/viw2.1 | |||||
権利 | ||||||
権利情報 | © 2020 The Author(s) | |||||
情報源 | ||||||
関連名称 | https://creativecommons.org/licenses/by/4.0/ | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://onlinelibrary.wiley.com/doi/10.1002/viw2.1 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |