{"_buckets": {"deposit": "e1f08a75-9c25-4a7f-897b-5c56574786c5"}, "_deposit": {"created_by": 31, "id": "2364", "owners": [31], "pid": {"revision_id": 0, "type": "depid", "value": "2364"}, "status": "published"}, "_oai": {"id": "oai:oist.repo.nii.ac.jp:00002364", "sets": ["213"]}, "author_link": ["15738", "15728", "15732", "15727", "15729", "15737", "15733", "15734", "15736", "15735", "15730", "15731"], "item_10001_biblio_info_7": {"attribute_name": "Bibliographic Information", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-09-23", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageStart": "113134", "bibliographicVolumeNumber": "332-1", "bibliographic_titles": [{}, {"bibliographic_title": "Sensors and Actuators A: Physical", "bibliographic_titleLang": "en"}]}]}, "item_10001_creator_3": {"attribute_name": "Author", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Liu, Dejun"}], "nameIdentifiers": [{"nameIdentifier": "15727", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Li, Wei"}], "nameIdentifiers": [{"nameIdentifier": "15728", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wu, Qiang"}], "nameIdentifiers": [{"nameIdentifier": "15729", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Zhao, Haoyu"}], "nameIdentifiers": [{"nameIdentifier": "15730", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ling, Fengzi"}], "nameIdentifiers": [{"nameIdentifier": "15731", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tian, Ke"}], "nameIdentifiers": [{"nameIdentifier": "15732", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shen, Changyu"}], "nameIdentifiers": [{"nameIdentifier": "15733", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Han, Wei"}], "nameIdentifiers": [{"nameIdentifier": "15734", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wei, Fangfang"}], "nameIdentifiers": [{"nameIdentifier": "15735", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Farrell, Gerald"}], "nameIdentifiers": [{"nameIdentifier": "15736", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Semenova, Yuliya"}], "nameIdentifiers": [{"nameIdentifier": "15737", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wang, Pengfei"}], "nameIdentifiers": [{"nameIdentifier": "15738", "nameIdentifierScheme": "WEKO"}]}]}, "item_10001_description_5": {"attribute_name": "Abstract", "attribute_value_mlt": [{"subitem_description": "Liquid level measurement in microfluidics is challenging, where a sensor with ultra-high sensitivity but miniature in nature is demanded. In this paper, we propose for the first time a microsized fiber sensor structure in both diameter and length for microfluidics applications, which is capable of sub-micrometer scale liquid level measurement. The sensor is simply fabricated by fusion splicing a short section of a hollow core fiber (HCF) between two singlemode fibers (SMFs). HCFs with different air core diameters (10 µm, 20 µm, 30 µm) were investigated and it is found that for a given length of HCF stronger resonant dips were excited in transmission for the HCF with a smaller air core diameter. Thus the HCF structure with an air core diameter of 10 µm (HCF-10) was used for demonstration of high sensitivity liquid level measurement in microfluidics. Simultaneous excitation of both Anti-Resonant Reflecting Optical Waveguide (ARROW) guiding mechanism and Mach-Zehnder interferometer (MZI) in transmission is demonstrated in such an HCF-10 structure when HCF-10 is longer than the critical length. A maximum sensitivity of 0.042 dB/µm (corresponding to a calculated liquid level resolution of ~0.23 µm) was experimentally achieved with an HCF-10 length of ~867 µm, which is three times higher than that of the previous reported to date of the most sensitive fiber optic liquid level sensors based on intensity modulation. In addition, the proposed sensor shows good repeatability of measurement and a very low cross sensitivity to changes in the surrounding refractive index.", "subitem_description_type": "Other"}]}, "item_10001_publisher_8": {"attribute_name": "Publisher", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "info:doi/10.1016/j.sna.2021.113134", "subitem_relation_type_select": "DOI"}}]}, "item_10001_relation_17": {"attribute_name": "Related site", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.sciencedirect.com/science/article/pii/S0924424721005999", "subitem_relation_type_select": "URI"}}]}, "item_10001_rights_15": {"attribute_name": "Rights", "attribute_value_mlt": [{"subitem_rights": "This article/chapter was published in Sensors and Actuators A: Physical, 332-1, Liu, D. J. Li, W. Wu, Q. Zhao, H. Y. Ling, F. Z. Tian, K. Shen, C. Y. Han, W. Wei, F. F. Farrell, G. Semenova, Y. Wang, P. F., High sensitivity liquid level sensor for microfluidic applications using a hollow core fiber structure, 113134, Copyright 2021 Elsevier B.V."}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0924-4247", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_version_type_20": {"attribute_name": "Author\u0027s flag", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2021-11-16"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "liquid level sensor-SNA-R2a.pdf", "filesize": [{"value": "2.7 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "CC BY-NC-ND 4.0\nCreative Commons Attribution-NonCommercial-NoDerivatives 4.0 International(https://creativecommons.org/licenses/by-nc-nd/4.0/)", "licensetype": "license_free", "mimetype": "application/pdf", "size": 2700000.0, "url": {"label": "liquid level sensor-SNA-R2a", "url": "https://oist.repo.nii.ac.jp/record/2364/files/liquid level sensor-SNA-R2a.pdf"}, "version_id": "04ed38c6-0fd5-409d-b58c-733cac510fc8"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Fiber sensor", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Hollow core fiber", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Antiresonant", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Mach-Zehnder interferometer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Liquid level", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "High sensitivity liquid level sensor for microfluidic applications using a hollow core fiber structure", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "High sensitivity liquid level sensor for microfluidic applications using a hollow core fiber structure", "subitem_title_language": "en"}]}, "item_type_id": "10001", "owner": "31", "path": ["213"], "permalink_uri": "https://oist.repo.nii.ac.jp/records/2364", "pubdate": {"attribute_name": "公開日", "attribute_value": "2021-11-16"}, "publish_date": "2021-11-16", "publish_status": "0", "recid": "2364", "relation": {}, "relation_version_is_last": true, "title": ["High sensitivity liquid level sensor for microfluidic applications using a hollow core fiber structure"], "weko_shared_id": 31}
High sensitivity liquid level sensor for microfluidic applications using a hollow core fiber structure
https://oist.repo.nii.ac.jp/records/2364
https://oist.repo.nii.ac.jp/records/236414a158ae-2fff-4243-b7c6-7afed88a8701
名前 / ファイル | ライセンス | アクション |
---|---|---|
liquid level sensor-SNA-R2a (2.7 MB)
|
CC BY-NC-ND 4.0
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International(https://creativecommons.org/licenses/by-nc-nd/4.0/) |
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-11-16 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | High sensitivity liquid level sensor for microfluidic applications using a hollow core fiber structure | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Fiber sensor | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Hollow core fiber | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Antiresonant | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Mach-Zehnder interferometer | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Liquid level | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者(英) |
Liu, Dejun
× Liu, Dejun× Li, Wei× Wu, Qiang× Zhao, Haoyu× Ling, Fengzi× Tian, Ke× Shen, Changyu× Han, Wei× Wei, Fangfang× Farrell, Gerald× Semenova, Yuliya× Wang, Pengfei |
|||||
書誌情報 |
en : Sensors and Actuators A: Physical 巻 332-1, 号 1, p. 113134, 発行日 2021-09-23 |
|||||
抄録 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Liquid level measurement in microfluidics is challenging, where a sensor with ultra-high sensitivity but miniature in nature is demanded. In this paper, we propose for the first time a microsized fiber sensor structure in both diameter and length for microfluidics applications, which is capable of sub-micrometer scale liquid level measurement. The sensor is simply fabricated by fusion splicing a short section of a hollow core fiber (HCF) between two singlemode fibers (SMFs). HCFs with different air core diameters (10 µm, 20 µm, 30 µm) were investigated and it is found that for a given length of HCF stronger resonant dips were excited in transmission for the HCF with a smaller air core diameter. Thus the HCF structure with an air core diameter of 10 µm (HCF-10) was used for demonstration of high sensitivity liquid level measurement in microfluidics. Simultaneous excitation of both Anti-Resonant Reflecting Optical Waveguide (ARROW) guiding mechanism and Mach-Zehnder interferometer (MZI) in transmission is demonstrated in such an HCF-10 structure when HCF-10 is longer than the critical length. A maximum sensitivity of 0.042 dB/µm (corresponding to a calculated liquid level resolution of ~0.23 µm) was experimentally achieved with an HCF-10 length of ~867 µm, which is three times higher than that of the previous reported to date of the most sensitive fiber optic liquid level sensors based on intensity modulation. In addition, the proposed sensor shows good repeatability of measurement and a very low cross sensitivity to changes in the surrounding refractive index. | |||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0924-4247 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | info:doi/10.1016/j.sna.2021.113134 | |||||
権利 | ||||||
権利情報 | This article/chapter was published in Sensors and Actuators A: Physical, 332-1, Liu, D. J. Li, W. Wu, Q. Zhao, H. Y. Ling, F. Z. Tian, K. Shen, C. Y. Han, W. Wei, F. F. Farrell, G. Semenova, Y. Wang, P. F., High sensitivity liquid level sensor for microfluidic applications using a hollow core fiber structure, 113134, Copyright 2021 Elsevier B.V. | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/pii/S0924424721005999 | |||||