{"created":"2023-06-26T11:01:19.610673+00:00","id":2006,"links":{},"metadata":{"_buckets":{"deposit":"d3b7409c-8e32-447e-b7c6-26aae7528461"},"_deposit":{"created_by":30,"id":"2006","owners":[30],"pid":{"revision_id":0,"type":"depid","value":"2006"},"status":"published"},"_oai":{"id":"oai:oist.repo.nii.ac.jp:00002006","sets":["6:31"]},"author_link":["13055","13053","13051","13052","13056","13054"],"item_10001_biblio_info_7":{"attribute_name":"Bibliographic Information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-11-27","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"454","bibliographicPageStart":"445","bibliographicVolumeNumber":"43","bibliographic_titles":[{},{"bibliographic_title":"Biotechnology Letters","bibliographic_titleLang":"en"}]}]},"item_10001_creator_3":{"attribute_name":"Author","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tardy, Gábor Márk"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Lóránt, Bálint"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Gyalai-Korpos, Miklós"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Bakos, Vince"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Simpson, David"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Goryanin, Igor"}],"nameIdentifiers":[{}]}]},"item_10001_description_5":{"attribute_name":"Abstract","attribute_value_mlt":[{"subitem_description":"OBJECTIVES: Single-chamber air cathode microbial fuel cells (MFCs) were applied as biosensors for biochemical oxygen demand (BOD) measurement of real wastewaters with considerable suspended and/or slowly biodegradable organic content. \nRESULTS: The measurement method consists of batch sample injection, continuous measurement of cell voltage and calculation of total charge (Q) gained during the biodegradation of organic content. Diverse samples were analyzed: acetate and peptone samples containing only soluble readily biodegradable substrates; corn starch and milk samples with suspended and colloidal organics; real domestic and brewery wastewaters. Linear regression fitted to the Q vs. BOD5 measurement points of the real wastewaters provided high (> 0.985) R(2) values. Time requirement of the measurement varied from 1 to 4 days, depending on the composition of the sample. \nCONCLUSIONS: Relative error of BOD measured in the MFCs comparing with BOD5 was less than 10%, thus the method might be a good basis for the development of on-site automatic BOD sensors for real wastewater samples.","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"Publisher","attribute_value_mlt":[{"subitem_publisher":"Springer Nature"}]},"item_10001_relation_13":{"attribute_name":"PubMedNo.","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"info:pmid/33245467","subitem_relation_type_select":"PMID"}}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"info:doi/10.1007/s10529-020-03050-5","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_17":{"attribute_name":"Related site","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://link.springer.com/article/10.1007%2Fs10529-020-03050-5","subitem_relation_type_select":"URI"}}]},"item_10001_rights_15":{"attribute_name":"Rights","attribute_value_mlt":[{"subitem_rights":"© 2020 The Author(s)."}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0141-5492","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"1573-6776","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"Author's flag","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-04-05"}],"displaytype":"detail","filename":"Tardy-2021-Microbial fuel cell biosensor for t.pdf","filesize":[{"value":"2.2 MB"}],"format":"application/pdf","license_note":"Creative Commons Attribution 4.0 International(https://creativecommons.org/licenses/by/4.0/)","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Tardy-2021-Microbial fuel cell biosensor for t","url":"https://oist.repo.nii.ac.jp/record/2006/files/Tardy-2021-Microbial fuel cell biosensor for t.pdf"},"version_id":"d907f7be-3104-4f7a-be25-ccb6d6c3401a"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Biochemical oxygen demand","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Biosensor","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Microbial fuel cell","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Wastewater characterization","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Microbial fuel cell biosensor for the determination of biochemical oxygen demand of wastewater samples containing readily and slowly biodegradable organics","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Microbial fuel cell biosensor for the determination of biochemical oxygen demand of wastewater samples containing readily and slowly biodegradable organics","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"30","path":["31"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-04-05"},"publish_date":"2021-04-05","publish_status":"0","recid":"2006","relation_version_is_last":true,"title":["Microbial fuel cell biosensor for the determination of biochemical oxygen demand of wastewater samples containing readily and slowly biodegradable organics"],"weko_creator_id":"30","weko_shared_id":30},"updated":"2023-06-26T11:38:56.578721+00:00"}