WEKO3
アイテム
Double photon emission coincidence imaging with GAGG-SiPM Compton camera
https://oist.repo.nii.ac.jp/records/1504
https://oist.repo.nii.ac.jp/records/150416f5c1e7-68cd-48fa-a160-197fb3e7a349
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International(https://creativecommons.org/licenses/by-nc-nd/4.0/)
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2020-05-15 | |||||||||||||||||||||||||||||||
タイトル | ||||||||||||||||||||||||||||||||
タイトル | Double photon emission coincidence imaging with GAGG-SiPM Compton camera | |||||||||||||||||||||||||||||||
言語 | en | |||||||||||||||||||||||||||||||
言語 | ||||||||||||||||||||||||||||||||
言語 | eng | |||||||||||||||||||||||||||||||
資源タイプ | ||||||||||||||||||||||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||||||||||||||||
資源タイプ | journal article | |||||||||||||||||||||||||||||||
著者(英) |
Uenomachi, Mizuki
× Uenomachi, Mizuki
× Mizumachi, Yuki
× Yoshihara, Yuri
× Takahashi, Hiroyuki
× Shimazoe, Kenji
× Yabu, Goro
× Yoneda, Hiroki
× Watanabe, Shin
× Takeda, Shin’ichiro
× Orita, Tadashi
× Takahashi, Tadayuki
× Moriyama, Fumiki
× Sugawara, Hirotaka
|
|||||||||||||||||||||||||||||||
書誌情報 |
en : Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 巻 954, p. 161682, 発行日 2018-12-08 |
|||||||||||||||||||||||||||||||
抄録 | ||||||||||||||||||||||||||||||||
内容記述タイプ | Other | |||||||||||||||||||||||||||||||
内容記述 | Compton imaging is a promising gamma-ray imaging method based on the Compton scattering kinematics due to high Compton scattering probability for sub-MeV to MeV gamma-rays. A conventional Compton camera has a disadvantage of low signal-to-background ratio (SBR), which is caused by drawing of multiple Compton cones. A method to solve this fundamental problem is the double-photon emission computed tomography (DPECT), which uses the coincidence detection for cascade gamma-rays and significantly increases the SBR using intersections of two Compton cones. In this study, we demonstrated the DPECT method by using 134Cs radio isotope, which is one of important radioisotopes for the imaging of fuel debris, with two Ce:Gd(Al,Ga)O12 (GAGG) scintillator Compton cameras. | |||||||||||||||||||||||||||||||
出版者 | ||||||||||||||||||||||||||||||||
出版者 | Elsevier | |||||||||||||||||||||||||||||||
ISSN | ||||||||||||||||||||||||||||||||
収録物識別子タイプ | ISSN | |||||||||||||||||||||||||||||||
収録物識別子 | 0168-9002 | |||||||||||||||||||||||||||||||
DOI | ||||||||||||||||||||||||||||||||
関連タイプ | isVersionOf | |||||||||||||||||||||||||||||||
識別子タイプ | DOI | |||||||||||||||||||||||||||||||
関連識別子 | info:doi/10.1016/j.nima.2018.11.141 | |||||||||||||||||||||||||||||||
権利 | ||||||||||||||||||||||||||||||||
権利情報 | © 2018 Elsevier B.V. | |||||||||||||||||||||||||||||||
情報源 | ||||||||||||||||||||||||||||||||
関連名称 | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |||||||||||||||||||||||||||||||
関連サイト | ||||||||||||||||||||||||||||||||
識別子タイプ | URI | |||||||||||||||||||||||||||||||
関連識別子 | https://www.sciencedirect.com/science/article/pii/S0168900218317947 | |||||||||||||||||||||||||||||||
著者版フラグ | ||||||||||||||||||||||||||||||||
出版タイプ | AM | |||||||||||||||||||||||||||||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |